DIP Switch Settings

The SEIKOSHA SP-1900Plus printer uses the following Dip Switch settings. Please refer to the printer manual for details of how to set these printers up.

Note: The printer must be turned off before you can change any of the switches. The current DIP Switch settings can be printed by holding down the NLQ switch whilst turning the printer on.

If you have been printing, allow the Print head to cool down before touching it. When setting the switches (below), open the printer cover, remove the ribbon cassette and replace the printer cover. The DIP switches are only read after the initialisation process either by turning the printer on or by receiving the INITIAL signal via the Parallel Interface.

Switch Function Description On Off
1

2

3

International Character see Table  
4 Standard / IBM emulation IBM Standard
5 Character set selection in IBM mode

1 inch selection in Standard (Epson) mode

Character Set 2

Valid

Character Set 1

Invalid

6 Page Length selection 12 inches 11 inches
7 LF Code Selection in IBM mode

DC1/DC3 Code selection in standard mode

LF+CR

Invalid

LF Only

Valid

8 CR Code selection in IBM mode

CR Code Selection in Standard mode

CR+LF

CR+LF

CR only

AUTOFEED

9 Character Set selection in Standard mode Graphic Italic
10 CSF Mode Entered Not Entered

Table 2: International Character Selection

Country Dip Switch

1

Dip Switch

2

Dip Switch

3

U.S.A ON ON ON
FRANCE ON ON OFF
GERMANY ON OFF ON
U.K ON OFF OFF
DENMARK OFF ON ON
SWEDEN OFF ON OFF
ITALY OFF OFF ON
SPAIN OFF OFF OFF

The following Test Prints are available on these printers. Turn Power on whilst holding down the following switch(es).

LF Self Test ASCII
NLQ Current Dip Switch settings
FF Hexadecimal dump

To exit from the self test mode or current Dip Switch settings, press the ON-LINE switch or turn the power off. To exit from Hexadecimal dump mode either turn the printer off or send an INITIAL signal via the Parallel Interface.