To change the setting after printing out the current settings (all 3 users).Turn the power switch
ON while pressing and holding the SET UP switch. The printer prints the current listing then enters the
setup mode
To change the setting after printing out the current settings (only the user number currently
selected by Function No.2). Press the SET UP switch while the printer is in the off-line status.
The printer prints the current listing of the user number selected by Function No. 3 then enters the
set up mode
Function |
Heading |
Function Description |
O1 |
Default Set |
Selects the Function set to be reset to factory default
|
O2 |
Select User |
Selects the Function set to use on Power on
|
O3 |
Change User |
Specifies which Function set is to be changed
|
O4 |
Emulation |
Choose between Epson (FX-1050) & IBM (ProPrinter III/IIIXL)
|
O5 |
Form Length |
Selects the default Form Length
|
O6 |
Line Spacing |
Select the default line spacing
|
O7 |
Line Length |
Select the default Right Margin
|
O8 |
Character Pitch |
Select the default character pitch
|
O9 |
Font Style |
Selects the default font.
|
10 |
Power On |
Sets the power on condition to the on-line or off-line status.
|
11 |
Quiet Mode |
Sets the power on condition to the quiet mode or not.
|
12 |
After Loading |
Selects the printer condition to the on line or off line status after autoloading the paper by the LOAD/PARK switch.
|
13 |
Print Direction |
Selects the print direction
|
14 |
Buffer Full |
Determines if a line feed will be added at the end of an over full line
|
15 |
CR Code |
Adds a line feed code to every carriage reurn code. If all your lines print on top of each other, select VALID (CR+LF)
|
16 |
LF Code |
Adds a carriage return code to every line feed code.
|
17 |
Cancel Code |
Sets the function of the CAN (cancel) code. If CAN is VALID, then the printer will cancel all the information in the input buffer when the CAN code is received. If CAN is INVALID, the CAN code is ignored.
|
18 |
Paper Empty Sensor |
Sets the paper empty sensor VALID or INVALID.
|
19 |
Skip Perforation |
Selects the skip-over perforation
|
20 |
Zero Character |
Selects a slashed or unslashed zero character
|
21 |
Selection of RAM |
Selects the capacity of the input buffer.** Only available when optional 32KB buffer extension fitted
|
22 |
ASF |
Selects the ASF installed or not installed.
|
23 |
Ribbon Mode |
Selects the black ribbon or color ribbon
|
24 |
Auto Tear Off |
Selects the timing for the auto tear off function
|
25 |
Tear Off Position |
Specifies a tear off condition with function No.22
|
26 |
Paper Initialization |
Selects the fanfold paper initialization
|
27 |
Buzzer |
Silences the printer buzzer
|
28 |
IBM Character Set |
This selects a character set in the IBM mode
|
29 |
Code Page |
Selects a code page in the IBM or Epson mode
|
30 |
IBM 20 PITCH |
Specifies the 20 PITCH mode of the IBM mode
|
31 |
Character Table |
Specifies the 80H-FFH character table used in the EPSON mode
|
32 |
International Character Table |
Selects the special foreign character set in the EPSON mode
|
50 |
Interface |
Selects the parallel or serial interface
|
51 |
Select in Signal |
Enables the function of the SELECT IN pin in the parallel interface
|
52 |
Autofeed XT signal |
Enables the function of the AUTOFEED XT pin the parallel interface
|
53 |
Protocol |
Selects the serial protocol
|
54 |
Baud Rate |
Selects the data transfer rate for the serial interface
|
55 |
Bit Length |
Selects the number of data bits for the serial interface |
56 |
Parity Bit |
Selects the parity for the serial interface |
57 |
Stop Bit Length |
Selects the number of stop bits for the serial interface |
58 |
CTS |
Overrides Clear to send (CTS) control on the serial interface |